Compliance Certification Services Inc.
Report No.: 70125004-D Date of Issue: January 29, 2007
Page 8 Rev. 00
6 INSTRUMENT AND CALIBRATION
6.1 MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been
calibrated once a year or in accordance with the manufacturer's recommendations, and is traceable
under the IEC 17025 to international or national standards. Equipment has been calibrated by
accredited calibration laboratories.
6.2 TEST AND MEASUREMENT EQUIPMENT
The following list contains measurement equipment used for testing. The equipment conforms to
the requirement of CISPR 16-1, ANSI C63.2 and other required standards.
Calibration of all test and measurement, including any accessories that may effect such
calibration, is checked frequently to ensure the accuracy. Adjustments are made and
correction factors are applied in accordance with the instructions contained in the respective
manual.
Equipment Used for Emission Measurement
Conducted Emission Test Site # 3
Name of Equipment Manufacturer Model Serial Number Calibration Due
EMI Test Receiver R&S ESCS30 847793/012 02/12/2007
Pulse Limiter R&S ESH3-Z2 100230 10/24/2007
LISN FCC
FCC-LISN-50/250-16-2-07
06013 10/08/2007
LISN R&S ENV 4200 830326/016 03/28/2007
Test S/W LabVIEW 6.1 (CCS Conduction Test SW Version_01)
Note: The measurement uncertainty is less than +/- 3.4509dB, which is evaluated as per the NAMAS NIS 81
and CISPR/A/291/CDV.