Compliance Certification Services Inc.
Report No.: 70125004-D Date of Issue: January 29, 2007
Page 12 Rev. 00
Procedure of Final Test
EUT and support equipment were set up on the test bench as per step 10 of the preliminary
test.
A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest
emissions. Emission frequency and amplitude were recorded into a computer in which
correction factors were used to calculate the emission level and compare reading to the
applicable limit. If EUT emission level was less –2dB to the AV. limit in Q.P. mode, then
the emission signal was re-checked using an AV. detector.
The test data of the worst-case condition(s) was recorded.
Data Sample:
Frequency
(MHz)
QuasiPeak
reading
(dBuV)
Average
reading
(dBuV)
Correctrion
factor
(dB)
QuasiPeak
result
(dBuV)
Average
result
(dBuV)
QuasiPeak.
limit
(dBuV)
Average
limit
(dBuV)
QuasiPeak
margin
(dB)
Average
margin
(dB)
Remark
x.xx 43.95 33 10.0 53.95 43 56.00 46.00 -2.05 -3 Pass
Frequency (MHz) = Emission frequency in MHz
Reading (dBuV) = Uncorrected Analyzer/Receiver reading + Insertion loss of LISN, if it > 0.5 dB
Correction Factor (dB) = Antenna factor + Cable loss – Amplifier gain
Result (dBuV) = Raw reading converted to dBuV and CF added
Limit (dBuV) = Limit stated in standard
Margin (dB) = Result (dBuV) – Limit (dBuV)